34-18-22.3 Fire safety standards for vacation home establishments.
34-18-22.3.
Fire safety standards for vacation home establishments.
Any vacation home
establishment shall meet the following minimum fire safety standards:
(1)
Each floor where ten or more occupants are sleeping shall have access to at least two
remote exits;
(2)
Any primary exit that leads to the exterior of the structure shall be capable of unlocking
from the interior without the use of a key or special knowledge or effort and free from
obstruction. Any sleeping room with a direct exit to the exterior of the building is exempt
from this requirement;
(3)
There shall be a smoke detector in each sleeping room. The owner or manager shall test
any battery operated smoke detector at least twice a year;
(4)
Any sleeping room shall be equipped with an operable egress window. Any sleeping room
with a direct exit to the exterior of the building is exempt from this requirement; and
(5)
A portable fire extinguisher with a minimum 2-A rating shall be made available on each
floor and shall be inspected and tagged annually.
Source: SL 2008, ch 172, § 2; SL 2011, ch 157, § 3.